Operation
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
SafeCheck 200 Operator’s Manual
13
3.4.3 Setup:
After turning the unit on, move through the main menu using the arrow
key until SETUP is highlighted. Press I/O, and the screen will ask you to
enter a four digit numeric password. For first time users or for users who
have forgotten their password, a default password was created. This four
digit default password is 9157.
The blinking cursor appears in place of the first digit. Press the arrow
key to scroll through the numbers from 9 down to 0.
Once you have reached the number you want, press
I/O, and the blinking cursor will appear in place of
the next digit. Repeat this process until the entire 4 digit password appears
on the screen. Then, when you press the I/O key, you will have
successfully accessed the SETUP menu.
The following items, will be found in the SETUP menu: Alarms Set,
Safety Chirp, Display Options, and Password. Press
the arrow key to cycle through them. Press the
I/O key to select the highlighted item.
As you are moving through most of the setup sub-menus, pressing the up
arrow key will return you to the previous menu.
• Alarms Set:
There are alarm activation levels for each of the sensors. While you may
alter any of the alarm activation levels, we recommend that you use the
default values which have been programmed into the unit. These values
are listed under Section 7. GAS SPECIFIC DATA on page 27.
Within the Setup menu, access ALARMS SET
by pressing the I/O key when ALARMS SET is
highlighted.
To change the alarm activation levels, first highlight a sensor using the
arrow key and then select it by pressing the I/O key.
For the OXYGEN sensor, both HI and LOW
alarm activation levels can be set.
Enter
Password: ---
Alarm Set
Safety Chirp
O2 LEL
Alarm Latch N
O2 HI Alrm 23.5
LO Alrm 19.5
Operation
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
SafeCheck 200 Operator’s Manual
14
For the combustible gas sensor (either LEL or
CH
4
), the HIGH LEVEL alarm activation level
can be set.
When Alarm Latch is highlighted, pressing the I/O key will change
between Y (yes) or N (no). This allows you to select whether the alarm
will turn off as soon as the hazard goes away (N) or
whether the alarm will latch (Y) until you
acknowledge it by pressing the I/O key. Once your
selection is made, press the arrow key to return to the SETUP menu or
the arrow key to change any of the sensor's alarm activation levels.
• Safety Chirp:
The SAFETY CHIRP feature, when enabled, provides an audio beep every
10 seconds in the RUN mode to inform the user that their unit is turned on
and is currently running.
Use the arrow key to move through the setup menu until you reach
SAFETY CHIRP Press the I/O key to access the
safety chirp menu. In this menu you have the
options of enabling or disabling the safety chirp.
To select whether or not the safety chirp feature is turned on, press the I/O
key while SAFETY CHIRP is highlighted. The letter on the right will
change between Y (YES) and N (NO).
• Display Options:
This menu allows you to select whether or not you wish to use the back-
light option. It also allows you to select whether to display the combustible
sensor (if present) as % LEL or % CH
4
(methane) by volume.
Select DISPLAY OPTIONS from the SETUP menu. Use the arrow key
to select BK_LIGHT or LEL. With BK_LIGHT highlighted, pressing the
I/O key will change between Y (YES) and N (NO).
The backlight option will illuminate the screen for 10 seconds each time a
key is pressed during the RUN mode and the
MAIN menu, when turning the unit on and off,
and when the unit goes into alarm. The
backlight is useful in low-light areas but will not
be noticed in bright areas.
LEL Alarm
Level: 10%
O2 LEL
Alarm Latch N
Safety Chirp Y
Bk_Light Y
LEL = % of CH4